Precision Digital

PDW30 Point-to-Point Wireless Bridge

New Arrival

Simple, straightforward way to get an analog, discrete, or Modbus® signal from where you have it to where you need it

Starting at
$1,599.00USD
Have questions? We're here to help!
Have questions? We're here to help!
Configure
The Precision Digital PDW30 provides a simple, straightforward way to get an analog, discrete (digital) or Modbus signal from where you have it to where you need it – without having to run wires! It’s a point-to-point wireless bridge that is virtually plug and play right out of the box.
 
The PDW30 consists of a primary and a secondary unit and communication between the two is by-directional. That means you can send 4-20 mA, discrete and Modbus signals from the primary unit to the secondary unit and also send completely different 4-20 mA, discrete and Modbus signals from the secondary unit to the primary unit. For instance, the primary unit could send a 4-20 mA signal to the secondary unit corresponding to the level in a tank and the secondary unit could send a 4-20 mA signal to the primary unit to control a valve.
 
Primary and secondary units are also equipped with four digital I/O that can each be independently programmed as an input or an output. A Loss of Signal warning is also available by connecting devices to the G and LS screw terminals.
 
To indicate alarm situations, both units can be equipped with an optional, field installable, two relay module. These relays are rated Form A (SPST) 5A.
 
The specified range between the primary and secondary unit is 1 mile line-of-sight outdoor and 500 feet indoor and repeaters are available to extend the range. A low-cost wireless survey tool, Model PDA10, is available to test the signal strength of your application before you buy. And if the PDW30 system does not work in your application, you can return it for full credit!
 
The PDW30 is available in either aluminum or stainless steel NEMA 4X, IP68 enclosures and these enclosures contain plenty of room for field wiring connections.
 
Most applications require minimal programming and can be operational in minutes. However, free programming software is available and if touch ups are needed after installation, the instrument can be programmed without removing the cover using CapTouch buttons.
 
A wide range of accessories, including mounting kits, antenna-related accessories, and repeaters are available. The antenna comes attached to the unit and can also be remotely located. High gain directional antennas are also offered.
• Signal Wire Replacement Bridge Consisting of a Matched Pair of Wireless Field Units
• Virtually Plug and Play Right out of Box
• Range: 1 Mile Line-of-Sight Outdoor, 500 Feet Indoor; Repeaters Available to Extend Range
• Wireless Transmission Between Primary and Secondary Unit of
◦ 4-20 mA (Separate Signals Going Both Ways)
◦ Discrete (4 digital I/O Signals Going Both Ways)
◦ RS-485 Modbus
• Inputs: (Wired to Units) 4-20 mA or 0-10 V (1), Discrete/Digital (up to 4), Modbus
• Outputs: (Wired to Units) 4-20 mA (1), Discrete/Digital (up to 4), Relays (2, optional), Modbus
• Loss of Signal (LoS) Digital Output
• PDA10 Signal Strength Survey Tool to "Try Before You Buy"
• Field Installable Relay Module with Two Form A (SPST) 5A Relays (Available for Both Units)
• Simple to Configure Using PDW Manager Programming Software and On-Board USB
• Backlit Display Provides Helpful Input & Output Information
• CapTouch Through-Glass Button Programming for Non-Advanced Settings
• Device Communication Secured by Enabling 128-bit AES Encryption
• Password Protection
• Remote Yagi Directional Antennas Available
• IP68, NEMA 4X Aluminum & Stainless Steel Enclosures With Plenty of Room for Field Wiring
• Operating Temperature Range: -55 to 75°C (-67 to 167°F)
• Conformal Coated PCBs for Dust & Humidity Protection
• Flange for Wall or Pipe Mounting; Loop for Stainless Steel Tag; Holes for Tamper-Proof Seal
• Conformal Coated PCBs for Dust & Humidity Protection
• 9-30 VDC Power
• 3-Year Warranty
Warranty3 years parts & labor
Shipping Weight5 lbs. (2.27 kg)
Shipping Dimensions17" x 14" x 9" (43.2 cm x 35.6 cm x 22.9 cm) (L x W X H)
Signal Connector Tightening Torque2.5 lb-in (0.28 Nm)
MountingMay be mounted directly to conduit. Two mounting holes for 1.5" pipe or wall mounting. See Mounting Dimensions on page 29 for mounting space requirements.
EnclosureCast aluminum with glass window, 0.30% max copper content, corrosion resistant powder coating, color: blue. NEMA 4X/IP68. Two ½" NPT threaded conduit openings. One ½" NPT stainless steel conduit plug with 10 mm hex key fitting installed.
ConnectionsRemovable screw terminal blocks accept 16 to 30 AWG wire.
EnvironmentalOperating temperature range: -40 to 65°C (display inoperable < -20 °C); Storage temperature range: -40 to 85°C; Relative humidity: 0 to 90% non-condensing
Isolation500 V
Non-Volatile MemoryAll programmed settings are stored in non-volatile memory for a minimum of ten years if power is lost.
Power12-28 VDC, 5 W max
PasswordA programmable password restricts modification of programmed settings.
Process/ Digital I/O DisplayPress the display button once to display the present analog input and output. Press the display button again to display digital I/O states.
RecalibrationAll inputs and outputs are calibrated at the factory. Recalibration is recommended at least every 12 months.
Programming MethodsFour programming buttons (behind glass) or PC with PDW Manager software.
Network IDField selectable: 0 - 99
Display OrientationDisplay may be mounted at 180° from default orientation
Display32-character dual-line alphanumeric dot matrix LCD display with backlight (4.68mm x 2.21mm characters)

 